-40%
110V Adjustable Pressure 0-4500Psi Air Compressor for PCP Paintball Tank Refile
$ 210.67
- Description
- Size Guide
Description
110V 4500 Psi PCP Air Compressor for Airgun PCP Paintball Tank Refile Autostop Automatic Shutdown After Full-FillingPrioducts Features:
1.Charging Rate: 30L/Min;1.0CFM;
2.Filling Time: About 10-20 Minutes to full filling 1liter Tanks(This machine more fit for less than 1L Tanks)
3.Working Pressure:20-30Mpa,200-300Bar;3000-4500PSI;
4.Electric Power:1.5KW / 2 HP
5.Voltage:110V/60hz/1p
6.Cooling Type:Seprated Water Cooling;
7.Pressure adjustment system with automatic stopping function - water cool auto stop;
8.Dimension:11.8*5.2*12.5"
9.Weight: About 44 lbs
Package list:
Water pump
water pipe
Replace the filter element (filter cotton)
Drain valve
O-Rings
Rupture Disk
Breathing nozzle
High pressure trachea with filter
Notice:
1. The bottle filling of the air compressor must be greater than the pressure of the gas cylinder to fill the bottle! 【Air Compressor Pressure>Cylinder Pressure】
2. Suggestion for bottle filling: ≤ 1L
3. Use of gas cylinder: paintball shooting
4. Recommended operating time of the machine (machine operating load range): The temperature cannot exceed 85°C
5. Estimated filling time:
Recommendations for filling 1L gas cylinders:
1) The cylinder pressure is 200bar, and the estimated time is 7min
2) The cylinder pressure is 300bar, and the estimated time is 10min
6,Please add illubricating oil before you start using the machine first,IS0250
Please read this operation manual carefully before installation and operation
This series are high pressure air compressor. It compresses atmosphere air go to pressure 20/30Mpa, 3000/4500psi, after be purified and separated by the filter and separator.
It discharge clean air accords to GB18435-2001 air quality standard.
It is widely be used for breathing of diving and fire fighting; paintball PCP shooting and other high pressure filed industries by its reliability, portability and easy to use.
■ Check the electric voltage in nameplate is same as your local electric supply
■ Check the lubricate oil has been put in before running
■ Increase rated pressure setting is forbidden
■ There is potential danger of pipe burst or connect fitting blow off under high pressure, please avoid body too near compressor when it running
■ For safety Don’t leave compressor and always keep eyes to look at until it reach rated pressure whether it is automatic stop or manual stop
Double Check the lubricate oil has been put in before running
General maintenance interval
△
Check
◆
replace
everytime
50 h
100 h
annually
Lube Oil
△
◆
◆
◆
Air intake filter
△
◆
◆
Safety valve
◆
Air hose
◆